summaryrefslogtreecommitdiffstats
Commit message (Collapse)AuthorAgeFilesLines
* glusterd: Changed clear-locks cmd to use trusted-volfile for its internal mountKrishnan Parthasarathi2012-02-291-1/+1
| | | | | | | | | Change-Id: Iba8add1802832d4fa7082bc6a68eee966ddc508b BUG: 798127 Signed-off-by: Krishnan Parthasarathi <kp@gluster.com> Reviewed-on: http://review.gluster.com/2846 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Amar Tumballi <amarts@redhat.com>
* cluster/rebalance: Fix expression in check_free_spaceshishir gowda2012-02-291-1/+1
| | | | | | | | | | | | | | Migration should fail if available space in dst < src The expression was evaluating otherwise Change-Id: Ief64ad8797e405d0cdc787eef49bfbf4051dffac BUG: 798864 Signed-off-by: shishir gowda <shishirng@gluster.com> Reviewed-on: http://review.gluster.com/2847 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Amar Tumballi <amarts@redhat.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* mgmt/glusterd: do not close the same fd twiceRaghavendra Bhat2012-02-291-2/+13
| | | | | | | | | | | | | In volfile generation part, if the close on the file stream for the volfile fails, then we should not again close the same file stream which may lead to undefined behavior. Change-Id: Idec00955eea11d5b2ea74574f8d4e53fa80c220a BUG: 798599 Signed-off-by: Raghavendra Bhat <raghavendrabhat@gluster.com> Reviewed-on: http://review.gluster.com/2843 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* perf/md-cache: hold lock on modification of md_cache structureAmar Tumballi2012-02-291-36/+69
| | | | | | | | | | | | | as it is possible that multiple fops can alter the content of md-cache structure from inode-ctx, we need to safe-guard the issue of corruption due to race conditions. Change-Id: Iea051f8f6adff7690d6d60f3cf82eda75150b449 Signed-off-by: Amar Tumballi <amarts@redhat.com> BUG: 798179 Reviewed-on: http://review.gluster.com/2834 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* cluster/stripe: Send xattr request in lookup even when type is INVALshishir gowda2012-02-291-2/+5
| | | | | | | | | Change-Id: I6f66b5aa39eaa5eadca2a91b1d4e948490f0aa06 BUG: 798161 Signed-off-by: shishir gowda <shishirng@gluster.com> Reviewed-on: http://review.gluster.com/2837 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Amar Tumballi <amarts@redhat.com>
* nfs: prevent crash during cthon lock testRajesh Amaravathi2012-02-291-5/+7
| | | | | | | | | | | | | When cthon was invoked to test nlm, the mount point would hang, and crash nfs server, and all the brick processes. This path fixes the crashes. Change-Id: Ide88adb7e25ea722b143bfd62e23361ff7be4b67 BUG: 798194 Signed-off-by: Rajesh Amaravathi <rajesh@redhat.com> Reviewed-on: http://review.gluster.com/2842 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* libglusterfs: Handle loc_copy for nameless locPranith Kumar K2012-02-291-13/+9
| | | | | | | | | BUG: 787671 Change-Id: I7601f482ae753ead83be16d1df33c2187e76dc5c Signed-off-by: Pranith Kumar K <pranithk@gluster.com> Reviewed-on: http://review.gluster.com/2825 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* protocol/client: send unique key to server during handshakeAmar Tumballi2012-02-291-2/+7
| | | | | | | | | | | | utilize the graph->id for making the key unique. Change-Id: I0c1b355aa901af88e65fd12cb9e0535318856867 BUG: 783982 Signed-off-by: Amar Tumballi <amarts@redhat.com> Reviewed-on: http://review.gluster.com/2831 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Jeff Darcy <jdarcy@redhat.com> Reviewed-by: Mohammed Junaid <junaid@redhat.com>
* nfs/doc: correctionsRajesh Amaravathi2012-02-291-21/+21
| | | | | | | | | | | | corrections in nfs configuration helpers displayed with "gluster volume set help". Change-Id: Iffc0d10eacbaea647270cd875d4cbd5f80333671 BUG: 771876 Signed-off-by: Rajesh Amaravathi <rajesh@redhat.com> Reviewed-on: http://review.gluster.com/2829 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* transport/socket: configuring tcp window-sizeRajesh Amaravathi2012-02-299-106/+133
| | | | | | | | | | | | | | | | | | | | | | | Till now, send and recieve buffer window sizes for sockets were set to a default glusterfs-specific value. Linux's default window sizes have been found to be better w.r.t performance, and hence, no more setting it to any default value. However, if one wishes, there's the new configuration option: network.tcp-window-size <sane_size> which takes a size value (int or human readable) and will set the window size of sockets for both clients and servers. Nfs clients will also be updated with the same. Change-Id: I841479bbaea791b01086c42f58401ed297ff16ea BUG: 795635 Signed-off-by: Rajesh Amaravathi <rajesh@redhat.com> Reviewed-on: http://review.gluster.com/2821 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Amar Tumballi <amarts@redhat.com> Reviewed-by: Jeff Darcy <jdarcy@redhat.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* storage/posix: In lookup check for buf->gfid being NULLshishir gowda2012-02-291-0/+6
| | | | | | | | | | | | | | There are few cases where create and lookup race. Lookup ends up getting a valid struct iatt, but with no gfid set. We need to check for gfid being 0, and handle it as an error. Signed-off-by: shishir gowda <shishirng@gluster.com> Change-Id: I36ae1978b325aff964cbc3b24730c1e993666267 BUG: 797167 Reviewed-on: http://review.gluster.com/2832 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Amar Tumballi <amarts@redhat.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* glusterd/mountbroker: fix handling of MEET mountbroker keywordCsaba Henk2012-02-271-0/+1
| | | | | | | | | Change-Id: I5331a17a772e9ef15e132b9f335e5ff9d70735b7 BUG: 765214 Signed-off-by: Csaba Henk <csaba@redhat.com> Reviewed-on: http://review.gluster.com/2817 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* locks/glusterd: Fixed clearing of posix locks from failing always.Krishnan Parthasarathi2012-02-272-1/+4
| | | | | | | | | Change-Id: Ieaf636c6f0d2aa1d001143a2d1433fce85dc8c7a BUG: 797042 Signed-off-by: Krishnan Parthasarathi <kp@gluster.com> Reviewed-on: http://review.gluster.com/2812 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Amar Tumballi <amarts@redhat.com>
* mgmt/glusterd: pass defrag_cmd in rsp dict for volume infoshishir gowda2012-02-271-0/+5
| | | | | | | | | | | | | glusterd_import_volinfo used to error out as it was not able to find the rebalance key in the dict Change-Id: Ife35a041072a8a978d7595e8381f68e624bd8da3 BUG: 797105 Signed-off-by: shishir gowda <shishirng@gluster.com> Reviewed-on: http://review.gluster.com/2814 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Amar Tumballi <amarts@redhat.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* mempool: add more counters to understand the usage scenarios properlyAmar Tumballi2012-02-275-7/+66
| | | | | | | | | | | | | | current design of mempool is to fallback to standard calloc/free if all the buffers in pool are exhausted. Understanding more about those numbers will help us to tune mempool parameters properly over time. Change-Id: I2c94373186f7c6a486caff2611c2d9df2c37db3c Signed-off-by: Amar Tumballi <amarts@redhat.com> BUG: 797730 Reviewed-on: http://review.gluster.com/2804 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Kaushal M <kaushal@redhat.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* glusterfsd: unref the dict and free the memory to avoid memleakRaghavendra Bhat2012-02-272-0/+3
| | | | | | | | | | Change-Id: Ib7a1f8cbab039fefb73dc35560a035d5688b0e32 BUG: 796186 Signed-off-by: Raghavendra Bhat <raghavendrabhat@gluster.com> Reviewed-on: http://review.gluster.com/2808 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Amar Tumballi <amarts@redhat.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* cli: Fix broken "volume set help/help-xml"Kaushal M2012-02-271-4/+3
| | | | | | | | | Change-Id: I4e71e67f32ff37cfe23bc77c0e27645ac495a247 BUG: 796040 Signed-off-by: Kaushal M <kaushal@redhat.com> Reviewed-on: http://review.gluster.com/2822 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* cli: Add 'exit' command.Vijay Bellur2012-02-272-0/+7
| | | | | | | | | | | | | Based on request at: http://community.gluster.org/i/make-cli-understand-command-exit/ Change-Id: I9116236a8c2f7767c88672b8d3d6565906bfc61f BUG: 797551 Signed-off-by: Vijay Bellur <vijay@gluster.com> Reviewed-on: http://review.gluster.com/2815 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Raghavendra Bhat <raghavendrabhat@gluster.com> Reviewed-by: Amar Tumballi <amarts@redhat.com>
* libglusterfs: fix GF_FREECsaba Henk2012-02-272-2/+2
| | | | | | | | | | | | | | | | | | | | | | | | Argument-taking macros should be possible to use with same syntax that of C functions. In particular (assuming FOO is a single-argument macro), FOO(bar) should break and if (cond) FOO(bar); else baz(); should compile. Change-Id: If852c128a7317dc0dda1c669be7c6af40501e48d BUG: 762061 Signed-off-by: Csaba Henk <csaba@redhat.com> Reviewed-on: http://review.gluster.com/2816 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Amar Tumballi <amarts@redhat.com>
* locks: Made dump locks formatting more 'readable'.Krishnan Parthasarathi2012-02-242-18/+39
| | | | | | | | | | | | | | Also, Added inode's path to dump locks. Added basename to entrylk dump output. Added whence field of range locks to dump output. Change-Id: Ifd3f8b585a52de7ff68cd54506619ac3eaedeecc BUG: 789858 Signed-off-by: Krishnan Parthasarathi <kp@gluster.com> Reviewed-on: http://review.gluster.com/798 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* Change rebalance log file namev3.3.0qa24Shylesh Kumar2012-02-231-1/+5
| | | | | | | | | | | | Log file name for the rebalance process should be <volname>-rebalance.log Change-Id: I1ed169cdc92b11058b80360086b3c1f7618064ef BUG: 795714 Signed-off-by: Shylesh Kumar <shylesh@gluster.com> Reviewed-on: http://review.gluster.com/2805 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Shishir Gowda <shishirng@gluster.com>
* glusterd: Modified server graph to have index xl above pumpKrishnan Parthasarathi2012-02-231-18/+18
| | | | | | | | | | | | | | Index xlator needs a resolved inode in the incoming xattrop request to perform its indexing. In the case of replace-brick pump xlator doesn't resolve the inode in the (fop) requests it sends 'downwards', leading to null gfid sent to index xlator. Change-Id: I6b6e7af4354670616bf342292df1a25c219dd9e9 BUG: 796171 Signed-off-by: Krishnan Parthasarathi <kp@gluster.com> Reviewed-on: http://review.gluster.com/2801 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Pranith Kumar Karampuri <pranithk@gluster.com>
* Introduce new extended attribute: node-uuidVenky Shankar2012-02-2210-181/+395
| | | | | | | | | | | | | | | | Request for trusted.glusterfs.node-uuid returns pathinfo like string but containing the UUID of glusterd instead of the backend path for the requested file. This info is benificial for tasks like parallel rebalance that will make use of the UUID for data locality. Change-Id: I766a09cc4a5f63aebd11c73107924a1b29242dcf BUG: 772610 Signed-off-by: Venky Shankar <vshankar@redhat.com> Reviewed-on: http://review.gluster.com/2614 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Shishir Gowda <shishirng@gluster.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* protocol/client: Pass correct dict in client_readdirpshishir gowda2012-02-222-1/+3
| | | | | | | | | | | Also, alloc entry->dict before calling unserialize to it. Change-Id: I8a9db93afd6e95e75307467cd654805780d7b467 BUG: 796534 Signed-off-by: shishir gowda <shishirng@gluster.com> Reviewed-on: http://review.gluster.com/2803 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* build: Changes to specfile for correctness and package relevance.Vijay Bellur2012-02-221-6/+13
| | | | | | | | | | | - Removes a stale dependency of glusterfs-client on glusterfs-core - Server specific shared libraries included in glusterfs-server package. Change-Id: I852304e6351a9a7864b2049f603e11f6a5601ffb BUG: 764702 Signed-off-by: Vijay Bellur <vijay@gluster.com> Reviewed-on: http://review.gluster.com/2797 Tested-by: Gluster Build System <jenkins@build.gluster.com>
* features/marker: Use loc.inode to obtain parent if loc.parent isn't set.Vijay Bellur2012-02-221-1/+13
| | | | | | | | | Change-Id: I89dddb19168a3ffb269afc9f6bcb2d7e7c9a69cd BUG: 790389 Signed-off-by: Vijay Bellur <vijay@gluster.com> Reviewed-on: http://review.gluster.com/2802 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Raghavendra Bhat <raghavendrabhat@gluster.com>
* glusterfsd: give out the error on screen when cmd is given without optionsAmar Tumballi2012-02-221-0/+13
| | | | | | | | | | | | | 'glusterfs' cmd would take default options when no option is given, but sometimes default option may not work, in that case, we need to provide usage output Change-Id: I2ebd342890da11d2afaa0a23ee3a01d87694ff28 BUG: 791198 Signed-off-by: Amar Tumballi <amarts@redhat.com> Reviewed-on: http://review.gluster.com/2790 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* glusterfsd: unref the dict and use dict_set_dynstr to avoid memleakRaghavendra Bhat2012-02-223-7/+13
| | | | | | | | | | | | | Unref the new dict and use proper dict api (dict_set_dynstr) to save data for displaying volume status information, which otherwise leads to memory leak in the process. Change-Id: Icb9ceb1a867c5b9759211a67027d983ab9b7e1c2 BUG: 796186 Signed-off-by: Raghavendra Bhat <raghavendrabhat@gluster.com> Reviewed-on: http://review.gluster.com/2799 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* cli: print the type of the inode in gluster volume status inode outputRaghavendra Bhat2012-02-221-3/+31
| | | | | | | | | | | | | | | | | | | | | | | | Instead of a number print the type of the inode in the output of gluster volume status inode. This is what the output symbols indicate. R -----> Regular file D -----> Directory L -----> symbolic Link B -----> Block special device C -----> Character special device F -----> FIFO S -----> Socket I -----> Invalid inode type Also supress a warning message displayed at the time of build. Change-Id: I5a2adfe044ce21d9da159652d4b6e25cd0a2fdca BUG: 796078 Signed-off-by: Raghavendra Bhat <raghavendrabhat@gluster.com> Reviewed-on: http://review.gluster.com/2794 Reviewed-by: Amar Tumballi <amarts@redhat.com> Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* protocol/client: Print correct error messagePranith Kumar K2012-02-221-1/+1
| | | | | | | | | Change-Id: Ic68626c4a205cd78b60831aa7bd838b6d8824fa1 BUG: 796195 Signed-off-by: Pranith Kumar K <pranithk@gluster.com> Reviewed-on: http://review.gluster.com/2800 Reviewed-by: Amar Tumballi <amarts@redhat.com> Tested-by: Gluster Build System <jenkins@build.gluster.com>
* mempool: adjustments in pool sizesAmar Tumballi2012-02-2231-56/+61
| | | | | | | | | | | | | | | | | * while creating 'rpc_clnt', the caller knows what would be the ideal load on it, so an extra argument to set some pool sizes * while creating 'rpcsvc', the caller knows what would be the ideal load of it, so an extra argument to set request pool size * cli memory footprint is reduced Change-Id: Ie245216525b450e3373ef55b654b4cd30741347f Signed-off-by: Amar Tumballi <amarts@redhat.com> BUG: 765336 Reviewed-on: http://review.gluster.com/2784 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* mount.glusterfs: multiple fixesAmar Tumballi2012-02-221-2/+3
| | | | | | | | | | | | | | * fix return value in case of proper 'backup-volfile-server' option, and actual default server based mount failed. * fix a syntax error (bug: 796050) Change-Id: I6a530c9b9431e46f45ec9eeb99f6103386dd10dc Signed-off-by: Amar Tumballi <amarts@redhat.com> BUG: 796101 Reviewed-on: http://review.gluster.com/2798 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* cluster/stripe: Readdirp should call lookup on entriesshishir gowda2012-02-222-50/+116
| | | | | | | | | | | | | We were calling stat on each entry. Also, the inode ctx needs to be populated with the stripe_fd_ctx_t. Signed-off-by: shishir gowda <shishirng@gluster.com> Change-Id: Ibaafa360f22b551d1609041f13a4339e22c95645 BUG: 795669 Signed-off-by: shishir gowda <shishirng@gluster.com> Reviewed-on: http://review.gluster.com/2795 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Amar Tumballi <amarts@redhat.com>
* cluster/afr: Don't trust the fd returned in open_cbkPranith Kumar K2012-02-221-4/+7
| | | | | | | | | Change-Id: Id7d85a38875e3675904fc134e54e723c6a0c4de2 BUG: 786766 Signed-off-by: Pranith Kumar K <pranithk@gluster.com> Reviewed-on: http://review.gluster.com/2792 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* features/locks: Don't access free'd memoryPranith Kumar K2012-02-221-3/+4
| | | | | | | | | Change-Id: I4e22ede84622f2c9c46cc0bc9f17bef73afa815c BUG: 796069 Signed-off-by: Pranith Kumar K <pranithk@gluster.com> Reviewed-on: http://review.gluster.com/2791 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* pump: Fixed undefined reference to fill_loc_info fn.Krishnan Parthasarathi2012-02-222-4/+8
| | | | | | | | | | | | | Changed function to pump_fill_loc_info since its use is relevant only in pump's context. Change-Id: I5be1a908f88328f732dacfd7eac18f0c62f49eb8 BUG: 796066 Signed-off-by: Krishnan Parthasarathi <kp@gluster.com> Reviewed-on: http://review.gluster.com/2796 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Pranith Kumar Karampuri <pranithk@gluster.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* libglusterfs/options: Cleanup xlator percent_sizet code.Harshavardhana2012-02-213-82/+97
| | | | | | | | | Change-Id: I1a39252d6c26f7e30b77ef682b8b3cdcde8a4a51 BUG: 769691 Signed-off-by: Harshavardhana <fharshav@redhat.com> Reviewed-on: http://review.gluster.com/2619 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Amar Tumballi <amarts@redhat.com>
* features/index: Set correct ret value in index_addPranith Kumar K2012-02-211-0/+2
| | | | | | | | | Change-Id: I6314ea25ef26920593a3113eb2951d18255db34f BUG: 763820 Signed-off-by: Pranith Kumar K <pranithk@gluster.com> Reviewed-on: http://review.gluster.com/2786 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Jeff Darcy <jdarcy@redhat.com>
* build: More rpmbuild friendly changesv3.3.0qa23Vijay Bellur2012-02-211-3/+3
| | | | | | | | | Change-Id: I7dcd5c6461bbddde3bcc3d2519777e4c8889fe52 BUG: 764702 Signed-off-by: Vijay Bellur <vijay@gluster.com> Reviewed-on: http://review.gluster.com/2788 Reviewed-by: Venky Shankar <vshankar@redhat.com> Tested-by: Gluster Build System <jenkins@build.gluster.com>
* build: rpmbuild friendly changesVijay Bellur2012-02-212-2/+2
| | | | | | | | | Change-Id: Ia1299d4404da0bd6787516924ebadcf9d6e021d1 BUG: 764702 Signed-off-by: Vijay Bellur <vijay@gluster.com> Reviewed-on: http://review.gluster.com/2785 Reviewed-by: Amar Tumballi <amarts@redhat.com> Tested-by: Gluster Build System <jenkins@build.gluster.com>
* glusterd/auth: 3.2.x compatibilityRajesh Amaravathi2012-02-214-52/+72
| | | | | | | | | | | | | volumes created with GlusterFS 3.2.x will be compatible with GlusterFS 3.3 w.r.t auth.allow enhancements Change-Id: I615e46d648e1270a7b856cd71fab24cfe791ddb8 BUG: 795634 Signed-off-by: Rajesh Amaravathi <rajesh@redhat.com> Reviewed-on: http://review.gluster.com/2779 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Krishnan Parthasarathi <kp@gluster.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* features/index: Fix fd leakPranith Kumar K2012-02-211-2/+5
| | | | | | | | | Change-Id: Ib01d03999b099369674495ce500f48d492758f91 BUG: 763820 Signed-off-by: Pranith Kumar K <pranithk@gluster.com> Reviewed-on: http://review.gluster.com/2781 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* libglusterfs: Warn on missing _cbk calls in xlatorPranith Kumar K2012-02-211-0/+6
| | | | | | | | | Change-Id: I44684b5eeca3674ed8d5b7b0120699bb3767e38d BUG: 763820 Signed-off-by: Pranith Kumar K <pranithk@gluster.com> Reviewed-on: http://review.gluster.com/2782 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Amar Tumballi <amarts@redhat.com>
* cli, glusterfsd: Fixes for "volume top {read,write}-perf"Kaushal M2012-02-214-23/+23
| | | | | | | | | | | | | | | Changed variables to use unsigned types, to support larger comninations of block_size * block_count Also increases cli time out for "volume top" ops to 600, to allow more time for glusterd to return the results to cli. Change-Id: I4b953799c78a5a184311f6f8c4a7a99dc9e87a07 BUG: 783980 Signed-off-by: Kaushal M <kaushal@redhat.com> Reviewed-on: http://review.gluster.com/2761 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Amar Tumballi <amarts@redhat.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* core: utilize mempool for frame->local allocationsAmar Tumballi2012-02-2159-375/+407
| | | | | | | | | | | | | | | in each translator, which uses 'frame->local', we are using GF_CALLOC/GF_FREE, which would be costly considering the number of allocation happening in a lifetime of 'fop'. It would be good to utilize the mem pool framework for xlator's local structures, so there is no allocation overhead. Change-Id: Ida6e65039a24d9c219b380aa1c3559f36046dc94 Signed-off-by: Amar Tumballi <amar@gluster.com> BUG: 765336 Reviewed-on: http://review.gluster.com/2772 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Anand Avati <avati@redhat.com>
* cluster/distribute: send the right 'dict' for check_is_linkfile()Amar Tumballi2012-02-212-12/+34
| | | | | | | | | | | | earlier we were using 'check_is_linkfile_wo_dict()' for readdirp_cbk(), which is no more required now. Change-Id: I52295e08f8c494b7a081cfc684164a7f72562d0d Signed-off-by: Amar Tumballi <amar@gluster.com> BUG: 794641 Reviewed-on: http://review.gluster.com/2763 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Anand Avati <avati@redhat.com>
* features/index: Add release, releasedir cbksPranith Kumar K2012-02-211-1/+40
| | | | | | | | | Change-Id: Ice45a0b4e953e270273aa4155a895d6ec033fda8 BUG: 763820 Signed-off-by: Pranith Kumar K <pranithk@gluster.com> Reviewed-on: http://review.gluster.com/2780 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>
* features/md-cache: Change strdup to gf_strdupVijay Bellur2012-02-211-1/+1
| | | | | | | | Change-Id: Ic96e7d38b988efab49f723c9d1d46f65037a84ed BUG: 795682 Reviewed-on: http://review.gluster.com/2783 Reviewed-by: Anand Avati <avati@redhat.com> Tested-by: Gluster Build System <jenkins@build.gluster.com>
* Honor O_SYNC etc. properly.Jeff Darcy2012-02-211-2/+28
| | | | | | | | | Change-Id: I3dd90fe230386ad5571c5e639f27460e3d003f0e BUG: 773100 Signed-off-by: Jeff Darcy <jdarcy@redhat.com> Reviewed-on: http://review.gluster.com/2626 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Anand Avati <avati@redhat.com>
* rpc/clnt: handle PARENT_DOWN event appropriatelyAmar Tumballi2012-02-219-41/+168
| | | | | | | | | | Change-Id: I4644e944bad4d240d16de47786b9fa277333dba4 BUG: 767862 Signed-off-by: Raghavendra G <raghavendra@gluster.com> Signed-off-by: Amar Tumballi <amarts@redhat.com> Reviewed-on: http://review.gluster.com/2735 Tested-by: Gluster Build System <jenkins@build.gluster.com> Reviewed-by: Vijay Bellur <vijay@gluster.com>