diff options
| author | Sanju Rakonde <srakonde@redhat.com> | 2018-09-25 23:36:48 +0530 | 
|---|---|---|
| committer | Shyamsundar Ranganathan <srangana@redhat.com> | 2018-10-05 14:39:50 +0000 | 
| commit | db461ad61abdd56b1075324d03c71639e3460eb1 (patch) | |
| tree | feb4b663c31b7d1c7ae5c22552434bb26fdc04f3 | |
| parent | 3d2ea677f1fe8fbbd6390eac340c87722ea999db (diff) | |
glusterd: make sure that brickinfo->uuid is not null
Problem: After an upgrade from the version where shared-brick-count
option is not present to a version which introduced this option
causes issue at the mount point i.e, size of the volume at mount
point will be reduced by shared-brick-count value times.
Cause: shared-brick-count is equal to the number of bricks that
are sharing the file system. gd_set_shared_brick_count() calculates
the shared-brick-count value based on uuid of the node and fsid of
the brick. https://review.gluster.org/#/c/glusterfs/+/19484 handles
setting of fsid properly during an upgrade path. This patch assumed
that when the code path is reached, brickinfo->uuid is non-null.
But brickinfo->uuid is null for all the bricks, as the uuid is null
https://review.gluster.org/#/c/glusterfs/+/19484 couldn't reached the
code path to set the fsid for bricks. So, we had fsid as 0 for all
bricks, which resulted in gd_set_shared_brick_count() to calculate
shared-brick-count in a wrong way. i.e, the logic written in
gd_set_shared_brick_count() didn't work as expected since fsid is 0.
Solution: Before control reaches the code path written by
https://review.gluster.org/#/c/glusterfs/+/19484,
adding a check for whether brickinfo->uuid is null and
if brickinfo->uuid is having null value, calling
glusterd_resolve_brick will set the brickinfo->uuid to a
proper value. When we have proper uuid, fsid for the bricks
will be set properly and shared-brick-count value will be
caluculated correctly.
Please take a look at the bug https://bugzilla.redhat.com/show_bug.cgi?id=1632889
for complete RCA
Steps followed to test the fix:
1. Created a 2 node cluster, the cluster is running with binary
which doesn't have shared-brick-count option
2. Created a 2x(2+1) volume and started it
3. Mouted the volume, checked size of volume using df
4. Upgrade to a version where shared-brick-count is introduced
(upgraded the nodes one by one i.e, stop the glusterd, upgrade the node
and start the glusterd).
5. after upgrading both the nodes, bumped up the cluster.op-version
6. At mount point, df shows the correct size for volume.
> BUG: 1632889
> Change-Id: Ib9f078aafb15e899a01086eae113270657ea916b
> Signed-off-by: Sanju Rakonde <srakonde@redhat.com>
(cherry picked from commit f1e9b878ce2067db83a0baa5f384eda87287719d)
fixes: bz#1633479
Change-Id: Ib9f078aafb15e899a01086eae113270657ea916b
Signed-off-by: Sanju Rakonde <srakonde@redhat.com>
| -rw-r--r-- | xlators/mgmt/glusterd/src/glusterd-store.c | 3 | 
1 files changed, 2 insertions, 1 deletions
diff --git a/xlators/mgmt/glusterd/src/glusterd-store.c b/xlators/mgmt/glusterd/src/glusterd-store.c index b6efac5a51a..2f10d3fbe7c 100644 --- a/xlators/mgmt/glusterd/src/glusterd-store.c +++ b/xlators/mgmt/glusterd/src/glusterd-store.c @@ -2602,6 +2602,8 @@ glusterd_store_retrieve_bricks (glusterd_volinfo_t *volinfo)                   * snapshot or snapshot restored volume this would be done post                   * creating the brick mounts                   */ +                if (gf_uuid_is_null(brickinfo->uuid)) +                        (void)glusterd_resolve_brick(brickinfo);                  if (brickinfo->real_path[0] == '\0' && !volinfo->is_snap_volume                      && gf_uuid_is_null (volinfo->restored_from_snap)) {                          /* By now if the brick is a local brick then it will be @@ -2610,7 +2612,6 @@ glusterd_store_retrieve_bricks (glusterd_volinfo_t *volinfo)                           * with MY_UUID for realpath check. Hence do not handle                           * error                           */ -                        (void)glusterd_resolve_brick (brickinfo);                          if (!gf_uuid_compare(brickinfo->uuid, MY_UUID)) {                                  if (!realpath (brickinfo->path, abspath)) {                                          gf_msg (this->name, GF_LOG_CRITICAL,  | 