parent | 16a3f0d020d23978b22a07354c25c654c88163a2 (diff) |
cluster/afr: Don't lookup/forget inodes
Problem:
All inodes that are looked-up are always forgotten without fail in
afr removing the benefits of them being in lru. This same code can
cause crashes if between inode_lookup, inode_forget in afr if the
top xlator does inode_forget(0).
Fix:
Don't use lookup/forget in afr. No benefits are there at the moment
for keeping this code. It is impossible to prevent top xlators to
do inode_forget(0). Found similar instances in ec
and removed them even though those code paths are not going to
be executed in any place other than heal-daemon.
BUG: 1321554
Change-Id: Ia4cb236178f7f129cc898d53f0bbd26f494a2a8d
Signed-off-by: Pranith Kumar K <pkarampu@redhat.com>
Reviewed-on: http://review.gluster.org/13834
Smoke: Gluster Build System <jenkins@build.gluster.com>
NetBSD-regression: NetBSD Build System <jenkins@build.gluster.org>
CentOS-regression: Gluster Build System <jenkins@build.gluster.com>
Reviewed-by: Anuradha Talur <atalur@redhat.com>
Diffstat (limited to 'xlators/cluster/ec')
-rw-r--r-- | xlators/cluster/ec/src/ec-heald.c | 12 |
1 files changed, 1 insertions, 11 deletions
diff --git a/xlators/cluster/ec/src/ec-heald.c b/xlators/cluster/ec/src/ec-heald.c index 2e5098a3612..0e8076826c6 100644 --- a/xlators/cluster/ec/src/ec-heald.c +++ b/xlators/cluster/ec/src/ec-heald.c @@ -137,10 +137,8 @@ ec_shd_inode_find (xlator_t *this, xlator_t *subvol, *inode = NULL; *inode = inode_find (this->itable, gfid); - if (*inode) { - inode_lookup (*inode); + if (*inode) goto out; - } loc.inode = inode_new (this->itable); if (!loc.inode) { @@ -157,8 +155,6 @@ ec_shd_inode_find (xlator_t *this, xlator_t *subvol, if (!*inode) { ret = -ENOMEM; goto out; - } else { - inode_lookup (*inode); } out: loc_wipe (&loc); @@ -267,8 +263,6 @@ out: uuid_utoa(loc.gfid)); ec_shd_index_purge (subvol, parent->inode, entry->d_name); } - if (loc.inode) - inode_forget (loc.inode, 0); loc_wipe (&loc); return 0; @@ -296,8 +290,6 @@ ec_shd_index_sweep (struct subvol_healer *healer) ret = syncop_dir_scan (subvol, &loc, GF_CLIENT_PID_SELF_HEALD, healer, ec_shd_index_heal); out: - if (loc.inode) - inode_forget (loc.inode, 0); loc_wipe (&loc); return ret; @@ -336,8 +328,6 @@ ec_shd_full_heal (xlator_t *subvol, gf_dirent_t *entry, loc_t *parent, ret = 0; out: - if (loc.inode) - inode_forget (loc.inode, 0); loc_wipe (&loc); return ret; } |