summaryrefslogtreecommitdiffstats
path: root/xlators/features/trash/src/trash.c
diff options
context:
space:
mode:
authorMohit Agrawal <moagrawa@redhat.com>2018-03-12 19:43:15 +0530
committerRaghavendra G <rgowdapp@redhat.com>2018-04-19 04:31:51 +0000
commit0043c63f70776444f69667a4ef9596217ecb42b7 (patch)
treee6c239e4b27198d40bca329edcce317ded59de09 /xlators/features/trash/src/trash.c
parentbe26b0da2f1a7fe336400de6a1c016716983bd38 (diff)
gluster: Sometimes Brick process is crashed at the time of stopping brick
Problem: Sometimes brick process is getting crashed at the time of stop brick while brick mux is enabled. Solution: Brick process was getting crashed because of rpc connection was not cleaning properly while brick mux is enabled.In this patch after sending GF_EVENT_CLEANUP notification to xlator(server) waits for all rpc client connection destroy for specific xlator.Once rpc connections are destroyed in server_rpc_notify for all associated client for that brick then call xlator_mem_cleanup for for brick xlator as well as all child xlators.To avoid races at the time of cleanup introduce two new flags at each xlator cleanup_starting, call_cleanup. BUG: 1544090 Signed-off-by: Mohit Agrawal <moagrawa@redhat.com> Note: Run all test-cases in separate build (https://review.gluster.org/#/c/19700/) with same patch after enable brick mux forcefully, all test cases are passed. Change-Id: Ic4ab9c128df282d146cf1135640281fcb31997bf updates: bz#1544090
Diffstat (limited to 'xlators/features/trash/src/trash.c')
-rw-r--r--xlators/features/trash/src/trash.c18
1 files changed, 13 insertions, 5 deletions
diff --git a/xlators/features/trash/src/trash.c b/xlators/features/trash/src/trash.c
index e8f8b7bf051..8a92685cf4b 100644
--- a/xlators/features/trash/src/trash.c
+++ b/xlators/features/trash/src/trash.c
@@ -2616,16 +2616,24 @@ fini (xlator_t *this)
GF_VALIDATE_OR_GOTO ("trash", this, out);
priv = this->private;
- inode_table = priv->trash_itable;
if (priv) {
- if (priv->newtrash_dir)
+ inode_table = priv->trash_itable;
+ if (priv->newtrash_dir) {
GF_FREE (priv->newtrash_dir);
- if (priv->oldtrash_dir)
+ priv->newtrash_dir = NULL;
+ }
+ if (priv->oldtrash_dir) {
GF_FREE (priv->oldtrash_dir);
- if (priv->brick_path)
+ priv->oldtrash_dir = NULL;
+ }
+ if (priv->brick_path) {
GF_FREE (priv->brick_path);
- if (priv->eliminate)
+ priv->brick_path = NULL;
+ }
+ if (priv->eliminate) {
wipe_eliminate_path (&priv->eliminate);
+ priv->eliminate = NULL;
+ }
if (inode_table) {
inode_table_destroy (inode_table);
priv->trash_itable = NULL;