diff options
author | M. Mohan Kumar <mohan@in.ibm.com> | 2013-11-13 22:44:42 +0530 |
---|---|---|
committer | Anand Avati <avati@redhat.com> | 2013-11-13 11:38:42 -0800 |
commit | 48c40e1a42efe1b59126406084821947d139dd0e (patch) | |
tree | 74959ecda9b9bd56c85e0e32991c11c06b022296 /xlators/mgmt/glusterd/src/glusterd-volgen.c | |
parent | 15a8ecd9b3eedf80881bd3dba81f16b7d2cb7c97 (diff) |
bd: posix/multi-brick support to BD xlator
Current BD xlator (block backend) has a few limitations such as
* Creation of directories not supported
* Supports only single brick
* Does not use extended attributes (and client gfid) like posix xlator
* Creation of special files (symbolic links, device nodes etc) not
supported
Basic limitation of not allowing directory creation is blocking
oVirt/VDSM to consume BD xlator as part of Gluster domain since VDSM
creates multi-level directories when GlusterFS is used as storage
backend for storing VM images.
To overcome these limitations a new BD xlator with following
improvements is suggested.
* New hybrid BD xlator that handles both regular files and block device
files
* The volume will have both POSIX and BD bricks. Regular files are
created on POSIX bricks, block devices are created on the BD brick (VG)
* BD xlator leverages exiting POSIX xlator for most POSIX calls and
hence sits above the POSIX xlator
* Block device file is differentiated from regular file by an extended
attribute
* The xattr 'user.glusterfs.bd' (BD_XATTR) plays a role in mapping a
posix file to Logical Volume (LV).
* When a client sends a request to set BD_XATTR on a posix file, a new
LV is created and mapped to posix file. So every block device will
have a representative file in POSIX brick with 'user.glusterfs.bd'
(BD_XATTR) set.
* Here after all operations on this file results in LV related
operations.
For example opening a file that has BD_XATTR set results in opening
the LV block device, reading results in reading the corresponding LV
block device.
When BD xlator gets request to set BD_XATTR via setxattr call, it
creates a LV and information about this LV is placed in the xattr of the
posix file. xattr "user.glusterfs.bd" used to identify that posix file
is mapped to BD.
Usage:
Server side:
[root@host1 ~]# gluster volume create bdvol host1:/storage/vg1_info?vg1 host2:/storage/vg2_info?vg2
It creates a distributed gluster volume 'bdvol' with Volume Group vg1
using posix brick /storage/vg1_info in host1 and Volume Group vg2 using
/storage/vg2_info in host2.
[root@host1 ~]# gluster volume start bdvol
Client side:
[root@node ~]# mount -t glusterfs host1:/bdvol /media
[root@node ~]# touch /media/posix
It creates regular posix file 'posix' in either host1:/vg1 or host2:/vg2 brick
[root@node ~]# mkdir /media/image
[root@node ~]# touch /media/image/lv1
It also creates regular posix file 'lv1' in either host1:/vg1 or
host2:/vg2 brick
[root@node ~]# setfattr -n "user.glusterfs.bd" -v "lv" /media/image/lv1
[root@node ~]#
Above setxattr results in creating a new LV in corresponding brick's VG
and it sets 'user.glusterfs.bd' with value 'lv:<default-extent-size'
[root@node ~]# truncate -s5G /media/image/lv1
It results in resizig LV 'lv1'to 5G
New BD xlator code is placed in xlators/storage/bd directory.
Also add volume-uuid to the VG so that same VG can't be used for other
bricks/volumes. After deleting a gluster volume, one has to manually
remove the associated tag using vgchange <vg-name> --deltag
<trusted.glusterfs.volume-id:<volume-id>>
Changes from previous version V5:
* Removed support for delayed deleting of LVs
Changes from previous version V4:
* Consolidated the patches
* Removed usage of BD_XATTR_SIZE and consolidated it in BD_XATTR.
Changes from previous version V3:
* Added support in FUSE to support full/linked clone
* Added support to merge snapshots and provide information about origin
* bd_map xlator removed
* iatt structure used in inode_ctx. iatt is cached and updated during
fsync/flush
* aio support
* Type and capabilities of volume are exported through getxattr
Changes from version 2:
* Used inode_context for caching BD size and to check if loc/fd is BD or
not.
* Added GlusterFS server offloaded copy and snapshot through setfattr
FOP. As part of this libgfapi is modified.
* BD xlator supports stripe
* During unlinking if a LV file is already opened, its added to delete
list and bd_del_thread tries to delete from this list when a last
reference to that file is closed.
Changes from previous version:
* gfid is used as name of LV
* ? is used to specify VG name for creating BD volume in volume
create, add-brick. gluster volume create volname host:/path?vg
* open-behind issue is fixed
* A replicate brick can be added dynamically and LVs from source brick
are replicated to destination brick
* A distribute brick can be added dynamically and rebalance operation
distributes existing LVs/files to the new brick
* Thin provisioning support added.
* bd_map xlator support retained
* setfattr -n user.glusterfs.bd -v "lv" creates a regular LV and
setfattr -n user.glusterfs.bd -v "thin" creates thin LV
* Capability and backend information added to gluster volume info (and
--xml) so
that management tools can exploit BD xlator.
* tracing support for bd xlator added
TODO:
* Add support to display snapshots for a given LV
* Display posix filename for list-origin instead of gfid
Change-Id: I00d32dfbab3b7c806e0841515c86c3aa519332f2
BUG: 1028672
Signed-off-by: M. Mohan Kumar <mohan@in.ibm.com>
Reviewed-on: http://review.gluster.org/4809
Tested-by: Gluster Build System <jenkins@build.gluster.com>
Reviewed-by: Anand Avati <avati@redhat.com>
Diffstat (limited to 'xlators/mgmt/glusterd/src/glusterd-volgen.c')
-rw-r--r-- | xlators/mgmt/glusterd/src/glusterd-volgen.c | 21 |
1 files changed, 21 insertions, 0 deletions
diff --git a/xlators/mgmt/glusterd/src/glusterd-volgen.c b/xlators/mgmt/glusterd/src/glusterd-volgen.c index 6bf14bc3daa..51fba4da343 100644 --- a/xlators/mgmt/glusterd/src/glusterd-volgen.c +++ b/xlators/mgmt/glusterd/src/glusterd-volgen.c @@ -594,6 +594,8 @@ get_server_xlator (char *xlator) subvol = GF_XLATOR_MARKER; if (strcmp (xlator, "io-stats") == 0) subvol = GF_XLATOR_IO_STATS; + if (strcmp (xlator, "bd") == 0) + subvol = GF_XLATOR_BD; return subvol; } @@ -1456,7 +1458,26 @@ server_graph_builder (volgen_graph_t *graph, glusterd_volinfo_t *volinfo, "posix"); if (ret) return -1; +#ifdef HAVE_BD_XLATOR + if (*brickinfo->vg != '\0') { + /* Now add BD v2 xlator if volume is BD type */ + xl = volgen_graph_add (graph, "storage/bd", volname); + if (!xl) + return -1; + + ret = xlator_set_option (xl, "device", "vg"); + if (ret) + return -1; + ret = xlator_set_option (xl, "export", brickinfo->vg); + if (ret) + return -1; + + ret = check_and_add_debug_xl (graph, set_dict, volname, "bd"); + if (ret) + return -1; + } +#endif xl = volgen_graph_add (graph, "features/changelog", volname); if (!xl) |