summaryrefslogtreecommitdiffstats
path: root/xlators/mount/fuse/src/fuse-bridge.c
diff options
context:
space:
mode:
authorPranith Kumar K <pkarampu@redhat.com>2020-05-29 14:24:53 +0530
committerRinku Kothiya <rkothiya@redhat.com>2020-08-27 20:24:44 +0000
commit2b08fde39de3182bfa11e4a22490aa80c004ab03 (patch)
tree6540068a1408f5d8a0de1702a823d73d518200e9 /xlators/mount/fuse/src/fuse-bridge.c
parent09fcf1c85f9fb68fbe0ad958310e9740fbfa19d7 (diff)
cluster/afr: Delay post-op for fsync
Problem: AFR doesn't delay post-op for fsync fop. For fsync heavy workloads this leads to un-necessary fxattrop/finodelk for every fsync leading to bad performance. Fix: Have delayed post-op for fsync. Add special flag in xdata to indicate that afr shouldn't delay post-op in cases where either the process will terminate or graph-switch would happen. Otherwise it leads to un-necessary heals when the graph-switch/process-termination happens before delayed-post-op completes. Fixes: #1253 Change-Id: I531940d13269a111c49e0510d49514dc169f4577 Signed-off-by: Pranith Kumar K <pkarampu@redhat.com>
Diffstat (limited to 'xlators/mount/fuse/src/fuse-bridge.c')
-rw-r--r--xlators/mount/fuse/src/fuse-bridge.c23
1 files changed, 20 insertions, 3 deletions
diff --git a/xlators/mount/fuse/src/fuse-bridge.c b/xlators/mount/fuse/src/fuse-bridge.c
index be1c08e9ca4..88567c10286 100644
--- a/xlators/mount/fuse/src/fuse-bridge.c
+++ b/xlators/mount/fuse/src/fuse-bridge.c
@@ -5588,6 +5588,7 @@ fuse_migrate_fd(xlator_t *this, fd_t *basefd, xlator_t *old_subvol,
char create_in_progress = 0;
fuse_fd_ctx_t *basefd_ctx = NULL;
fd_t *oldfd = NULL;
+ dict_t *xdata = NULL;
basefd_ctx = fuse_fd_ctx_get(this, basefd);
GF_VALIDATE_OR_GOTO("glusterfs-fuse", basefd_ctx, out);
@@ -5624,10 +5625,23 @@ fuse_migrate_fd(xlator_t *this, fd_t *basefd, xlator_t *old_subvol,
}
if (oldfd->inode->table->xl == old_subvol) {
- if (IA_ISDIR(oldfd->inode->ia_type))
+ if (IA_ISDIR(oldfd->inode->ia_type)) {
ret = syncop_fsyncdir(old_subvol, oldfd, 0, NULL, NULL);
- else
- ret = syncop_fsync(old_subvol, oldfd, 0, NULL, NULL, NULL, NULL);
+ } else {
+ xdata = dict_new();
+ if (!xdata || dict_set_int8(xdata, "last-fsync", 1)) {
+ gf_log("glusterfs-fuse", GF_LOG_WARNING,
+ "last-fsync set failed (%s) on fd (%p)"
+ "(basefd:%p basefd-inode.gfid:%s) "
+ "(old-subvolume:%s-%d new-subvolume:%s-%d)",
+ strerror(ENOMEM), oldfd, basefd,
+ uuid_utoa(basefd->inode->gfid), old_subvol->name,
+ old_subvol->graph->id, new_subvol->name,
+ new_subvol->graph->id);
+ }
+
+ ret = syncop_fsync(old_subvol, oldfd, 0, NULL, NULL, xdata, NULL);
+ }
if (ret < 0) {
gf_log("glusterfs-fuse", GF_LOG_WARNING,
@@ -5682,6 +5696,9 @@ out:
fd_unref(oldfd);
+ if (xdata)
+ dict_unref(xdata);
+
return ret;
}