diff options
author | Raghavendra G <raghavendra@gluster.com> | 2012-03-07 21:02:16 +0530 |
---|---|---|
committer | Vijay Bellur <vijay@gluster.com> | 2012-03-08 19:22:02 -0800 |
commit | bc10ade1cff9d6cd3b3528ec6c845efadc722481 (patch) | |
tree | bc3f1b0edf9e96bffd0cd39a56996290673bc73f /xlators/performance/io-cache/src/ioc-inode.c | |
parent | 204ab142977163f634cbf4ec92be58754225504a (diff) |
performance/io-cache: pass appropriate op_errno even during successful
reads.
An op_errno equal to ENOENT with op_ret equal to zero is used by
storage/posix xlator to indicate EOF. NFS relies on this protocol
for correct functioning.
Change-Id: I136fbf429a829bd7bd75ce8ce236f9557a418a5d
BUG: 795789
Signed-off-by: Raghavendra G <raghavendra@gluster.com>
Reviewed-on: http://review.gluster.com/2894
Tested-by: Gluster Build System <jenkins@build.gluster.com>
Reviewed-by: Vijay Bellur <vijay@gluster.com>
Diffstat (limited to 'xlators/performance/io-cache/src/ioc-inode.c')
-rw-r--r-- | xlators/performance/io-cache/src/ioc-inode.c | 3 |
1 files changed, 2 insertions, 1 deletions
diff --git a/xlators/performance/io-cache/src/ioc-inode.c b/xlators/performance/io-cache/src/ioc-inode.c index 4c48c41d1b7..a99d5ea99e9 100644 --- a/xlators/performance/io-cache/src/ioc-inode.c +++ b/xlators/performance/io-cache/src/ioc-inode.c @@ -123,7 +123,8 @@ ioc_inode_wakeup (call_frame_t *frame, ioc_inode_t *ioc_inode, ioc_inode_lock (ioc_inode); { page_waitq = - __ioc_page_wakeup (waiter_page); + __ioc_page_wakeup (waiter_page, + 0); } ioc_inode_unlock (ioc_inode); if (page_waitq) |