diff options
author | Mohammed Rafi KC <rkavunga@redhat.com> | 2015-04-23 23:13:50 +0530 |
---|---|---|
committer | Vijay Bellur <vbellur@redhat.com> | 2015-05-10 06:26:49 -0700 |
commit | 32e5cdeaa5073437d396c1e7d39c0fe4cbe1ee87 (patch) | |
tree | e2937f185c8b0ea56abf71cf7aa3f7a8ed55161b /xlators | |
parent | 4eaaf5188fe24a4707dc2cf2934525083cf8e64f (diff) |
uss : implement statfs fop for snapd
snapview-client and snapview-server doesnot have statfs
fop implemented
Change-Id: I2cdd4c5784414b0549a01af9a28dbc723b7cdc67
BUG: 1176837
Signed-off-by: Mohammed Rafi KC <rkavunga@redhat.com>
Reviewed-on: http://review.gluster.org/10358
Tested-by: Gluster Build System <jenkins@build.gluster.com>
Reviewed-by: Niels de Vos <ndevos@redhat.com>
Reviewed-by: Avra Sengupta <asengupt@redhat.com>
Tested-by: NetBSD Build System
Reviewed-by: Vijay Bellur <vbellur@redhat.com>
Diffstat (limited to 'xlators')
-rw-r--r-- | xlators/features/snapview-client/src/snapview-client.c | 59 | ||||
-rw-r--r-- | xlators/features/snapview-server/src/snapview-server.c | 53 |
2 files changed, 112 insertions, 0 deletions
diff --git a/xlators/features/snapview-client/src/snapview-client.c b/xlators/features/snapview-client/src/snapview-client.c index 8351922af24..2f304aa7d3f 100644 --- a/xlators/features/snapview-client/src/snapview-client.c +++ b/xlators/features/snapview-client/src/snapview-client.c @@ -498,6 +498,64 @@ out: return 0; } +int32_t +svc_statfs (call_frame_t *frame, xlator_t *this, loc_t *loc, + dict_t *xdata) +{ + xlator_t *subvolume = NULL; + int32_t ret = -1; + int inode_type = -1; + int32_t op_ret = -1; + int32_t op_errno = EINVAL; + gf_boolean_t wind = _gf_false; + svc_private_t *priv = NULL; + const char *path = NULL; + int path_len = -1; + int snap_len = -1; + loc_t root_loc = {0,}; + loc_t *temp_loc = NULL; + + GF_VALIDATE_OR_GOTO ("svc", this, out); + GF_VALIDATE_OR_GOTO (this->name, frame, out); + GF_VALIDATE_OR_GOTO (this->name, loc, out); + GF_VALIDATE_OR_GOTO (this->name, loc->inode, out); + + priv = this->private; + SVC_GET_SUBVOL_FROM_CTX (this, op_ret, op_errno, inode_type, ret, + loc->inode, subvolume, out); + path_len = strlen (loc->path); + snap_len = strlen (priv->path); + temp_loc = loc; + + if (path_len >= snap_len && inode_type == VIRTUAL_INODE) { + path = &loc->path[path_len - snap_len]; + if (!strcmp (path, priv->path)) { + /* + * statfs call for virtual snap directory. + * Sent the fops to parent volume by removing + * virtual directory from path + */ + subvolume = FIRST_CHILD (this); + root_loc.path = "/"; + gf_uuid_clear(root_loc.gfid); + root_loc.gfid[15] = 1; + root_loc.inode = loc->inode->table->root; + root_loc.inode->ia_type = IA_IFDIR; + temp_loc = &root_loc; + } + } + + STACK_WIND_TAIL (frame, subvolume, subvolume->fops->statfs, + temp_loc, xdata); + + wind = _gf_true; +out: + if (!wind) + SVC_STACK_UNWIND (statfs, frame, op_ret, op_errno, + NULL, NULL); + return 0; +} + /* should all the fops be handled like lookup is supposed to be handled? i.e just based on inode type decide where the call should be sent and in the call back update the contexts. @@ -2303,6 +2361,7 @@ struct xlator_fops fops = { .opendir = svc_opendir, .stat = svc_stat, .fstat = svc_fstat, + .statfs = svc_statfs, .rmdir = svc_rmdir, .rename = svc_rename, .mkdir = svc_mkdir, diff --git a/xlators/features/snapview-server/src/snapview-server.c b/xlators/features/snapview-server/src/snapview-server.c index 035dd54d1f9..3415ce0d671 100644 --- a/xlators/features/snapview-server/src/snapview-server.c +++ b/xlators/features/snapview-server/src/snapview-server.c @@ -1800,6 +1800,58 @@ out: } int32_t +svs_statfs (call_frame_t *frame, xlator_t *this, loc_t *loc, dict_t *xdata) +{ + svs_private_t *priv = NULL; + struct statvfs buf = {0, }; + int32_t op_errno = EINVAL; + int32_t op_ret = -1; + svs_inode_t *inode_ctx = NULL; + glfs_t *fs = NULL; + glfs_object_t *object = NULL; + int ret = -1; + + GF_VALIDATE_OR_GOTO ("snap-view-daemon", this, out); + GF_VALIDATE_OR_GOTO (this->name, frame, out); + GF_VALIDATE_OR_GOTO (this->name, loc, out); + GF_VALIDATE_OR_GOTO (this->name, loc->inode, out); + + priv = this->private; + + /* Instead of doing the check of whether it is a entry point directory + or not by checking the name of the entry and then deciding what + to do, just check the inode context and decide what to be done. + */ + inode_ctx = svs_inode_ctx_get (this, loc->inode); + if (!inode_ctx) { + gf_log (this->name, GF_LOG_ERROR, "inode context not found for" + " %s", uuid_utoa (loc->inode->gfid)); + op_ret = -1; + op_errno = EINVAL; + goto out; + } + + SVS_GET_INODE_CTX_INFO(inode_ctx, fs, object, this, loc, op_ret, + op_errno, out); + + ret = glfs_h_statfs (fs, object, &buf); + if (ret) { + gf_log (this->name, GF_LOG_ERROR, "glfs_h_statvfs on %s " + "(gfid: %s) failed", loc->name, + uuid_utoa (loc->inode->gfid)); + op_ret = -1; + op_errno = errno; + goto out; + } + op_ret = ret; + +out: + STACK_UNWIND_STRICT (statfs, frame, op_ret, op_errno, &buf, xdata); + return 0; +} + + +int32_t svs_open (call_frame_t *frame, xlator_t *this, loc_t *loc, int32_t flags, fd_t *fd, dict_t *xdata) { @@ -2218,6 +2270,7 @@ fini (xlator_t *this) struct xlator_fops fops = { .lookup = svs_lookup, .stat = svs_stat, + .statfs = svs_statfs, .opendir = svs_opendir, .readdirp = svs_readdirp, .readdir = svs_readdir, |