diff options
Diffstat (limited to 'xlators/protocol/server/src/server-common.c')
| -rw-r--r-- | xlators/protocol/server/src/server-common.c | 68 | 
1 files changed, 55 insertions, 13 deletions
diff --git a/xlators/protocol/server/src/server-common.c b/xlators/protocol/server/src/server-common.c index 1dc3a9cf9bd..b972918f37f 100644 --- a/xlators/protocol/server/src/server-common.c +++ b/xlators/protocol/server/src/server-common.c @@ -10,8 +10,24 @@  #include "xdr-nfs3.h"  void -server_post_stat (gfs3_stat_rsp *rsp, struct iatt *stbuf) +server_post_stat (server_state_t *state, gfs3_stat_rsp *rsp, struct iatt *stbuf)  { +        if (state->client->subdir_mount) { +                if (gf_uuid_compare (stbuf->ia_gfid, +                                     state->client->subdir_gfid)) { +                        /* This is very important as when we send iatt of +                           root-inode, fuse/client expect the gfid to be 1, +                           along with inode number. As for subdirectory mount, +                           we use inode table which is shared by everyone, but +                           make sure we send fops only from subdir and below, +                           we have to alter inode gfid and send it to client */ +                        uuid_t gfid = {0,}; + +                        gfid[15] = 1; +                        stbuf->ia_ino = 1; +                        gf_uuid_copy (stbuf->ia_gfid, gfid); +                } +        }          gf_stat_from_iatt (&rsp->stat, stbuf);  } @@ -166,8 +182,25 @@ server_post_ftruncate (gfs3_ftruncate_rsp *rsp, struct iatt *prebuf,  }  void -server_post_fstat (gfs3_fstat_rsp *rsp, struct iatt *stbuf) +server_post_fstat (server_state_t *state, gfs3_fstat_rsp *rsp, +                   struct iatt *stbuf)  { +        if (state->client->subdir_mount) { +                if (gf_uuid_compare (stbuf->ia_gfid, +                                     state->client->subdir_gfid)) { +                        /* This is very important as when we send iatt of +                           root-inode, fuse/client expect the gfid to be 1, +                           along with inode number. As for subdirectory mount, +                           we use inode table which is shared by everyone, but +                           make sure we send fops only from subdir and below, +                           we have to alter inode gfid and send it to client */ +                        uuid_t gfid = {0,}; + +                        gfid[15] = 1; +                        stbuf->ia_ino = 1; +                        gf_uuid_copy (stbuf->ia_gfid, gfid); +                } +        }          gf_stat_from_iatt (&rsp->stat, stbuf);  } @@ -444,17 +477,6 @@ server_post_lookup (gfs3_lookup_rsp *rsp, call_frame_t *frame,          root_inode = frame->root->client->bound_xl->itable->root; -        if (inode == root_inode) { -                /* we just looked up root ("/") */ -                stbuf->ia_ino = 1; -                rootgfid[15]  = 1; -                gf_uuid_copy (stbuf->ia_gfid, rootgfid); -                if (inode->ia_type == 0) -                        inode->ia_type = stbuf->ia_type; -        } - -        gf_stat_from_iatt (&rsp->stat, stbuf); -          if (!__is_root_gfid (inode->gfid)) {                  link_inode = inode_link (inode, state->loc.parent,                                           state->loc.name, stbuf); @@ -463,6 +485,26 @@ server_post_lookup (gfs3_lookup_rsp *rsp, call_frame_t *frame,                          inode_unref (link_inode);                  }          } + +        if ((inode == root_inode) || +            (state->client->subdir_mount && +             (inode == state->client->subdir_inode))) { +                /* we just looked up root ("/") OR +                   subdir mount directory, which is root ('/') in client */ +                /* This is very important as when we send iatt of +                   root-inode, fuse/client expect the gfid to be 1, +                   along with inode number. As for subdirectory mount, +                   we use inode table which is shared by everyone, but +                   make sure we send fops only from subdir and below, +                   we have to alter inode gfid and send it to client */ +                stbuf->ia_ino = 1; +                rootgfid[15]  = 1; +                gf_uuid_copy (stbuf->ia_gfid, rootgfid); +                if (inode->ia_type == 0) +                        inode->ia_type = stbuf->ia_type; +        } + +        gf_stat_from_iatt (&rsp->stat, stbuf);  }  void  | 
