summaryrefslogtreecommitdiffstats
path: root/xlators/protocol/server/src/server-common.c
diff options
context:
space:
mode:
Diffstat (limited to 'xlators/protocol/server/src/server-common.c')
-rw-r--r--xlators/protocol/server/src/server-common.c374
1 files changed, 370 insertions, 4 deletions
diff --git a/xlators/protocol/server/src/server-common.c b/xlators/protocol/server/src/server-common.c
index 9c38706dbcb..17660ef475e 100644
--- a/xlators/protocol/server/src/server-common.c
+++ b/xlators/protocol/server/src/server-common.c
@@ -5,6 +5,7 @@
#include "glusterfs3.h"
#include "compat-errno.h"
#include "server-messages.h"
+#include "server-helpers.h"
#include "defaults.h"
#include "fd.h"
#include "xdr-nfs3.h"
@@ -229,9 +230,9 @@ server_post_lk (xlator_t *this, gfs3_lk_rsp *rsp, struct gf_flock *lock)
int
server_post_readdir (gfs3_readdir_rsp *rsp, gf_dirent_t *entries)
{
- int ret = 0;
+ int ret = 0;
- ret = serialize_rsp_dirent (entries, rsp);
+ ret = serialize_rsp_dirent (entries, rsp);
return ret;
}
@@ -268,9 +269,9 @@ server_post_seek (gfs3_seek_rsp *rsp, off_t offset)
int
server_post_readdirp (gfs3_readdirp_rsp *rsp, gf_dirent_t *entries)
{
- int ret = 0;
+ int ret = 0;
- ret = serialize_rsp_direntp (entries, rsp);
+ ret = serialize_rsp_direntp (entries, rsp);
return ret;
}
@@ -512,3 +513,368 @@ server_post_lease (gfs3_lease_rsp *rsp, struct gf_lease *lease)
{
gf_proto_lease_from_lease (&rsp->lease, lease);
}
+
+
+/* Version 4 helpers */
+
+void
+server4_post_readlink (gfx_readlink_rsp *rsp, struct iatt *stbuf,
+ const char *buf)
+{
+ gfx_stat_from_iattx (&rsp->buf, stbuf);
+ rsp->path = (char *)buf;
+}
+
+void
+server4_post_common_3iatt (server_state_t *state, gfx_common_3iatt_rsp *rsp,
+ inode_t *inode, struct iatt *stbuf,
+ struct iatt *preparent, struct iatt *postparent)
+{
+ inode_t *link_inode = NULL;
+
+ gfx_stat_from_iattx (&rsp->stat, stbuf);
+ if (state->client->subdir_mount &&
+ !gf_uuid_compare (preparent->ia_gfid,
+ state->client->subdir_gfid)) {
+ /* This is very important as when we send iatt of
+ root-inode, fuse/client expect the gfid to be 1,
+ along with inode number. As for subdirectory mount,
+ we use inode table which is shared by everyone, but
+ make sure we send fops only from subdir and below,
+ we have to alter inode gfid and send it to client */
+ uuid_t gfid = {0,};
+
+ gfid[15] = 1;
+ preparent->ia_ino = 1;
+ postparent->ia_ino = 1;
+ gf_uuid_copy (preparent->ia_gfid, gfid);
+ gf_uuid_copy (postparent->ia_gfid, gfid);
+ }
+
+ gfx_stat_from_iattx (&rsp->preparent, preparent);
+ gfx_stat_from_iattx (&rsp->postparent, postparent);
+
+ link_inode = inode_link (inode, state->loc.parent,
+ state->loc.name, stbuf);
+ inode_lookup (link_inode);
+ inode_unref (link_inode);
+}
+
+void
+server4_post_common_2iatt (gfx_common_2iatt_rsp *rsp, struct iatt *prebuf,
+ struct iatt *postbuf)
+{
+ gfx_stat_from_iattx (&rsp->prestat, prebuf);
+ gfx_stat_from_iattx (&rsp->poststat, postbuf);
+}
+
+void
+server4_post_entry_remove (server_state_t *state, gfx_common_2iatt_rsp *rsp,
+ struct iatt *prebuf, struct iatt *postbuf)
+{
+ inode_unlink (state->loc.inode, state->loc.parent,
+ state->loc.name);
+ /* parent should not be found for directories after
+ * inode_unlink, since directories cannot have
+ * hardlinks.
+ */
+ forget_inode_if_no_dentry (state->loc.inode);
+
+ gfx_stat_from_iattx (&rsp->prestat, prebuf);
+ gfx_stat_from_iattx (&rsp->poststat, postbuf);
+}
+
+
+void
+server4_post_statfs (gfx_statfs_rsp *rsp, struct statvfs *stbuf)
+{
+ gf_statfs_from_statfs (&rsp->statfs, stbuf);
+}
+
+void
+server4_post_common_iatt (server_state_t *state, gfx_common_iatt_rsp *rsp,
+ struct iatt *stbuf)
+{
+ if (state->client->subdir_mount &&
+ !gf_uuid_compare (stbuf->ia_gfid,
+ state->client->subdir_gfid)) {
+ /* This is very important as when we send iatt of
+ root-inode, fuse/client expect the gfid to be 1,
+ along with inode number. As for subdirectory mount,
+ we use inode table which is shared by everyone, but
+ make sure we send fops only from subdir and below,
+ we have to alter inode gfid and send it to client */
+ uuid_t gfid = {0,};
+
+ gfid[15] = 1;
+ stbuf->ia_ino = 1;
+ gf_uuid_copy (stbuf->ia_gfid, gfid);
+ }
+
+ gfx_stat_from_iattx (&rsp->stat, stbuf);
+}
+
+void
+server4_post_lk (xlator_t *this, gfx_lk_rsp *rsp, struct gf_flock *lock)
+{
+ switch (lock->l_type) {
+ case F_RDLCK:
+ lock->l_type = GF_LK_F_RDLCK;
+ break;
+ case F_WRLCK:
+ lock->l_type = GF_LK_F_WRLCK;
+ break;
+ case F_UNLCK:
+ lock->l_type = GF_LK_F_UNLCK;
+ break;
+ default:
+ gf_msg (this->name, GF_LOG_ERROR, 0, PS_MSG_LOCK_ERROR,
+ "Unknown lock type: %"PRId32"!", lock->l_type);
+ break;
+ }
+
+ gf_proto_flock_from_flock (&rsp->flock, lock);
+}
+
+int
+server4_post_readdir (gfx_readdir_rsp *rsp, gf_dirent_t *entries)
+{
+ int ret = 0;
+
+ ret = serialize_rsp_dirent_v2 (entries, rsp);
+
+ return ret;
+}
+
+void
+server4_post_seek (gfx_seek_rsp *rsp, off_t offset)
+{
+ rsp->offset = offset;
+}
+
+int
+server4_post_readdirp (gfx_readdirp_rsp *rsp, gf_dirent_t *entries)
+{
+ int ret = 0;
+
+ ret = serialize_rsp_direntp_v2 (entries, rsp);
+
+ return ret;
+}
+
+void
+server4_post_rchecksum (gfx_rchecksum_rsp *rsp, uint32_t weak_checksum,
+ uint8_t *strong_checksum)
+{
+ rsp->weak_checksum = weak_checksum;
+
+ rsp->strong_checksum.strong_checksum_val = (char *)strong_checksum;
+ rsp->strong_checksum.strong_checksum_len = SHA256_DIGEST_LENGTH;
+
+}
+
+void
+server4_post_rename (call_frame_t *frame,
+ server_state_t *state, gfx_rename_rsp *rsp,
+ struct iatt *stbuf,
+ struct iatt *preoldparent,
+ struct iatt *postoldparent,
+ struct iatt *prenewparent,
+ struct iatt *postnewparent)
+{
+ inode_t *tmp_inode = NULL;
+
+ stbuf->ia_type = state->loc.inode->ia_type;
+
+ /* TODO: log gfid of the inodes */
+ gf_msg_trace (frame->root->client->bound_xl->name, 0, "%"PRId64": "
+ "RENAME_CBK %s ==> %s", frame->root->unique,
+ state->loc.name, state->loc2.name);
+
+ /* Before renaming the inode, we have to get the inode for the
+ * destination entry (i.e. inode with state->loc2.parent as
+ * parent and state->loc2.name as name). If it exists, then
+ * unlink that inode, and send forget on that inode if the
+ * unlinked entry is the last entry. In case of fuse client
+ * the fuse kernel module itself sends the forget on the
+ * unlinked inode.
+ */
+ tmp_inode = inode_grep (state->loc.inode->table,
+ state->loc2.parent, state->loc2.name);
+ if (tmp_inode) {
+ inode_unlink (tmp_inode, state->loc2.parent,
+ state->loc2.name);
+ forget_inode_if_no_dentry (tmp_inode);
+ inode_unref (tmp_inode);
+ }
+
+ inode_rename (state->itable,
+ state->loc.parent, state->loc.name,
+ state->loc2.parent, state->loc2.name,
+ state->loc.inode, stbuf);
+ gfx_stat_from_iattx (&rsp->stat, stbuf);
+
+ gfx_stat_from_iattx (&rsp->preoldparent, preoldparent);
+ gfx_stat_from_iattx (&rsp->postoldparent, postoldparent);
+
+ gfx_stat_from_iattx (&rsp->prenewparent, prenewparent);
+ gfx_stat_from_iattx (&rsp->postnewparent, postnewparent);
+
+}
+
+int
+server4_post_open (call_frame_t *frame, xlator_t *this,
+ gfx_open_rsp *rsp, fd_t *fd)
+{
+ server_ctx_t *serv_ctx = NULL;
+ uint64_t fd_no = 0;
+
+ serv_ctx = server_ctx_get (frame->root->client, this);
+ if (serv_ctx == NULL) {
+ gf_msg (this->name, GF_LOG_INFO, 0,
+ PS_MSG_SERVER_CTX_GET_FAILED, "server_ctx_get() "
+ "failed");
+ return -1;
+ }
+
+ fd_bind (fd);
+ fd_ref (fd);
+ fd_no = gf_fd_unused_get (serv_ctx->fdtable, fd);
+ rsp->fd = fd_no;
+
+ return 0;
+}
+
+void
+server4_post_readv (gfx_read_rsp *rsp, struct iatt *stbuf, int op_ret)
+{
+ gfx_stat_from_iattx (&rsp->stat, stbuf);
+ rsp->size = op_ret;
+}
+
+int
+server4_post_create (call_frame_t *frame, gfx_create_rsp *rsp,
+ server_state_t *state,
+ xlator_t *this, fd_t *fd, inode_t *inode,
+ struct iatt *stbuf, struct iatt *preparent,
+ struct iatt *postparent)
+{
+ server_ctx_t *serv_ctx = NULL;
+ inode_t *link_inode = NULL;
+ uint64_t fd_no = 0;
+ int op_errno = 0;
+
+ link_inode = inode_link (inode, state->loc.parent,
+ state->loc.name, stbuf);
+
+ if (!link_inode) {
+ op_errno = ENOENT;
+ goto out;
+ }
+
+ if (link_inode != inode) {
+ /*
+ VERY racy code (if used anywhere else)
+ -- don't do this without understanding
+ */
+
+ inode_ctx_merge (fd, fd->inode, link_inode);
+ inode_unref (fd->inode);
+ fd->inode = inode_ref (link_inode);
+ }
+
+ inode_lookup (link_inode);
+ inode_unref (link_inode);
+
+ serv_ctx = server_ctx_get (frame->root->client, this);
+ if (serv_ctx == NULL) {
+ gf_msg (this->name, GF_LOG_INFO, 0,
+ PS_MSG_SERVER_CTX_GET_FAILED, "server_ctx_get() "
+ "failed");
+ goto out;
+ }
+
+ fd_bind (fd);
+ fd_ref (fd);
+ fd_no = gf_fd_unused_get (serv_ctx->fdtable, fd);
+
+ if ((fd_no > UINT64_MAX) || (fd == 0)) {
+ op_errno = errno;
+ }
+
+ rsp->fd = fd_no;
+ gfx_stat_from_iattx (&rsp->stat, stbuf);
+ gfx_stat_from_iattx (&rsp->preparent, preparent);
+ gfx_stat_from_iattx (&rsp->postparent, postparent);
+
+ return 0;
+out:
+ return -op_errno;
+}
+
+/*TODO: Handle revalidate path */
+void
+server4_post_lookup (gfx_common_2iatt_rsp *rsp, call_frame_t *frame,
+ server_state_t *state,
+ inode_t *inode, struct iatt *stbuf)
+{
+ inode_t *root_inode = NULL;
+ inode_t *link_inode = NULL;
+ uuid_t rootgfid = {0,};
+
+ root_inode = frame->root->client->bound_xl->itable->root;
+
+ if (!__is_root_gfid (inode->gfid)) {
+ link_inode = inode_link (inode, state->loc.parent,
+ state->loc.name, stbuf);
+ if (link_inode) {
+ inode_lookup (link_inode);
+ inode_unref (link_inode);
+ }
+ }
+
+ if ((inode == root_inode) ||
+ (state->client->subdir_mount &&
+ (inode == state->client->subdir_inode))) {
+ /* we just looked up root ("/") OR
+ subdir mount directory, which is root ('/') in client */
+ /* This is very important as when we send iatt of
+ root-inode, fuse/client expect the gfid to be 1,
+ along with inode number. As for subdirectory mount,
+ we use inode table which is shared by everyone, but
+ make sure we send fops only from subdir and below,
+ we have to alter inode gfid and send it to client */
+ stbuf->ia_ino = 1;
+ rootgfid[15] = 1;
+ gf_uuid_copy (stbuf->ia_gfid, rootgfid);
+ if (inode->ia_type == 0)
+ inode->ia_type = stbuf->ia_type;
+ }
+
+ gfx_stat_from_iattx (&rsp->prestat, stbuf);
+}
+
+void
+server4_post_lease (gfx_lease_rsp *rsp, struct gf_lease *lease)
+{
+ gf_proto_lease_from_lease (&rsp->lease, lease);
+}
+
+void
+server4_post_link (server_state_t *state, gfx_common_3iatt_rsp *rsp,
+ inode_t *inode,
+ struct iatt *stbuf, struct iatt *preparent,
+ struct iatt *postparent, dict_t *xdata)
+{
+ inode_t *link_inode = NULL;
+
+ gfx_stat_from_iattx (&rsp->stat, stbuf);
+ gfx_stat_from_iattx (&rsp->preparent, preparent);
+ gfx_stat_from_iattx (&rsp->postparent, postparent);
+
+ link_inode = inode_link (inode, state->loc2.parent,
+ state->loc2.name, stbuf);
+ inode_lookup (link_inode);
+ inode_unref (link_inode);
+
+}